Soil Remediation
26 April 2018

Urban Remediation

 

Urban regeneration (revitalization in the US) is a common strategic objective for Governments and Cities alike.  Take the London 2012 Olympics as a prime example. 

The enabling works cleaned up an area of East London which was heavily contaminated as a result of former industrial activity. 

Soil Remediation
26 April 2018

Soil Remediation

 

Remediation (the action of reversing or stopping environmental damage) and health risk assessment are increasingly required by both industry and property developers as more is understood about risks from contaminated land, and regulations become more stringent. 

Remediation of an industrial site may be required when an environmental permit is surrendered, or following an accidental release of pollutants to land.  Similarly, it is often required in order to obtain planning permission and develop the site.

Soil Remediation
25 April 2018

Soil Remediation: An Urban Future

 

According to professional services firm, Pricewaterhouse Coopers (PwC), our future is set to be urban. 

They say that:-

  • More than half the world’s population already live in urban areas
  • 5 million people are added to the global urban population every week
Humidity
23 April 2018

Can Humidity Interference Affect PID Results?

 

A common frequently asked question is “can humidity interference affect my PID detector results?”  Like many sensors and measurement instrumentation, traditional PIDs can indeed be affected by the environmental conditions i.e. dust, dirt and in particular, humidity.  The major producers of oil & gas are located in the Gulf States and in or close to the Gulf of Mexico, which are of course areas of high temperature and high humidity. 

Humidity can disrupt PID measurements in two ways leading to false low or conversely high readings. 

The cause of low readings is because water vapour absorbs the photons released by ionisation within the sensor as can be seen in the simplified cross sections of a PID sensor (figure 1).

Humidity
23 April 2018

Oil & Gas Production

 

Thinking about process industries such as the oil & gas sector, it is well knowing that during normal operations, leaks can occur from pumps, valves, flanges, storage tanks or during loading and unloading. 

According to US EPA figures2, this can mean hundreds of tons of volatile organic compounds (VOC) including benzene, which pose a serious health risk3.

Fixed and personal photoionisation detectors (PIDs) have proven to be an ideal solution for VOC detection because they afford protection for individual workers (and their co-workers), and have high level audible, visual (and vibratory) alarms which activate when exposure levels exceed set thresholds.

Humidity
23 April 2018

What is humidity?

 

Humidity is a natural phenomenon and is an amount of water vapour present in the atmosphere or in a gas. 

Water vapour itself is the gaseous state of water and is invisible to the human eye but we have all experienced how uncomfortable high humidity can make you feel.

Humidity comes from water evaporating from lakes and oceans and since warmer water evaporates more quickly you find the most humid regions closer to warm bodies of water, like the Red Sea, the Persian Gulf and Miami, Florida.

Fire Investigation
11 April 2018

Fire Investigator's Kit

 

 

To assist the fire investigator, maximise their ‘productivity’ and minimise the number of lab samples that need to be taken, a number of useful accessories and spares should be provided:-

  • Long, flexible probe, to enable access to awkward spaces and gaps between floorboards and ceilings
  • Vehicle adaptor to keep the rechargeable battery topped up plus AA battery pack for ‘emergency use’
  • Exhaust barb to allow air samples to be captured whilst measuring for subsequent lab analysis if required
  • Bump test pen & calibration gas to check functionality and accuracy
  • Spare PTFE filters
  • Rugged carrying case

 

Fire Investigation
11 April 2018

Ease of Calibration & Maintenance

 

 

Conventional PIDs may use humidity suppression/compensation techniques but each of them has disadvantages:

  • Humidity sensor – these typically have a slower response than the PID sensor itself which causes a drifting compensation
  • Desiccant tube – these both slow the PID response and also reduce it by adsorption plus they need replacing from time to time which adds cost
  • Humidify the calibration gas – this only works at one level of humidity and is no longer accurate when the humidity changes

Importantly none of these solutions solves a false positive at high humidity

 

Benzene
10 April 2018

A Complete Guide to Benzene

 

 
Why is Benzene so hazardous?
 

VOCs have a significant vapour pressure at normal ambient temperature which means they evaporate (volatilise) at low temperatures so they can easily enter the body through normal breathing but can also be absorbed through the skin or by swallowing material containing it.

The effects on worker’s health depends upon how much benzene they are exposed to and for how long and as with other organic solvents, the immediate effects of a single exposure to a high concentration (hundreds of ppm) e.g. from a fugitive process leak, include headache, tiredness, nausea, dizziness and even unconsciousness if the exposure is very high (thousands of ppm) meaning an acute safety incident.

Humidity
9 April 2018

Solving the Problem of Humidity

 

 

Conventional PIDs may use humidity suppression/compensation techniques but each of them has disadvantages:

  • Humidity sensor – these typically have a slower response than the PID sensor itself which causes a drifting compensation
  • Desiccant tube – these both slow the PID response and also reduce it by adsorption plus they need replacing from time to time which adds cost
  • Humidify the calibration gas – this only works at one level of humidity and is no longer accurate when the humidity changes

Importantly none of these solutions solves a false positive at high humidity

 

Fire Investigation
5 April 2018

Effects of high humidity on photoionisation detectors (PIDs)

There are a few important issues to look out for when choosing an instrument. Like many sensors and measurement instrumentation, traditional PIDs can be affected by the adverse environmental conditions such as those found at fire scenes i.e. dirt, water and humidity.  The situation in the immediate aftermath of a fire is therefore not ideal and in particular the presence of high humidity can disrupt PID measurements leading to false low or conversely high readings. 

The cause of low readings is because water vapour absorbs the photons normally released by ionisation within the sensor as can be seen in the simplified cross sections of a PID (figure 1).

Fire Investigation
5 April 2018

Sniffer Dogs for Fire & Arson Investigation?

The principal goal for fire investigators is figuring out how and where a fire started and where foul play is suspected, specially trained arson detection dogs are amongst their ‘tools of the trade’. It is common knowledge that dogs have a keen sense of smell, but the actual degree of sensitivity is amazing.

 

Smell is a dog’s primary sense, and it is 10,000 to 100,000 times more acute than humans.  That analogous to being able to see and recognise something 500 meters away, a dog could see and recognize the same object 5000 kilometres away.  Or, if you could taste a teaspoon of sugar in your coffee, a dog could taste a teaspoon of sugar in over 3.5 million litres of water. Read more! 

Fire Investigation
4 April 2018

5 reasons for using a PID for Arson Investigation

There are several good reasons to use a PID for arson investigation:-
  • PIDs are portable and battery powered making them ideal for field applications
  • PIDs are a quick, simple to use and accurate method for the detection of accelerants at a fire scene
  • PIDs are very sensitive to commonly found accelerants and will detect hundreds of gasses and vapours
  • PIDs are non-destructive and will not affect the air sample which can be captured for further lab analysis
  • PIDs reduce the quantity and cost of lab samples required to reach a conclusion as to the cause of the fire

 

Fire Investigation
3 April 2018

Photoionisation Detector (PID) for Arson Investigation

 

One such tool for the detection of accelerants at fire scenes recommended by investigators3 is the photoionisation detector (PID) which has already proven to be an ideal solution for the detection of relatively low level VOCs for health & safety and environmental applications. 

These devices are battery powered and portable and can be deployed rapidly and safely to test areas between floorboards and under carpets where residual traces of accelerant may remain.